Airport Lighting Cable
Airfield Ground Lighting Series (FLYCY / FLYCWBY / FL2XCY / FLN2XCY)
Our Airfield Ground Lighting (AGL) cables are designed specifically for the demanding constant-current series circuits of modern airports. Engineered with high-integrity dielectric materials and robust shielding, these cables supply power to crucial runway, taxiway, approach, and obstruction visual guidance systems. They are formulated to withstand extreme environmental stress, direct burial, water immersion, and constant chemical contact in aviation zones.
Airport Lighting Cable - FLYCY
Standard airfield ground lighting series cable featuring Class 1 solid/Class 2 stranded copper conductor, high-grade PVC insulation, concentric copper wire screen with counter-helix copper tape, and robust PVC outer sheath. Ideal for standard underground airport installations and Constant Current Regulator (CCR) circuits.
✈ Catalog Subtypes & Dimension Registry
Review the standard industrial sub-configurations and engineering designations of this cable series.
| CABLE VARIANT | VOLTAGE RATING | INDUSTRY STANDARD |
|---|---|---|
| FLYCY 1/2 kV (6/2.5 re) | 1/2 kV | DIN VDE 0265 |
| FLYCY 1/2 kV (6/2.5 rm) | 1/2 kV | DIN VDE 0265 |
| FLYCY 1.5/3 kV (6/2.5 re) | 1.5/3 kV | DIN VDE 0265 |
| FLYCY 1.5/3 kV (6/2.5 rm) | 1.5/3 kV | DIN VDE 0265 |
| FLYCY 2.5/5 kV (6/4 re) | 2.5/5 kV | DIN VDE 0265 |
| FLYCY 2.5/5 kV (6/4 rm) | 2.5/5 kV | DIN VDE 0265 |
| FLYCY 3.6/6 kV (6/4 re) | 3.6/6 kV | DIN VDE 0265 |
| FLYCY 3.6/6 kV (6/4 rm) | 3.6/6 kV | DIN VDE 0265 |
| FLYCY 3.6/6 kV (6/6 re) | 3.6/6 kV | DIN VDE 0265 |
| FLYCY 3.6/6 kV (6/6 rm) | 3.6/6 kV | DIN VDE 0265 |
Direct WhatsApp Specification Inquiry
Have custom design requests or need physical sample slices of FLYCY? Consult with our product engineering team instantly via WhatsApp.
Airport Lighting Cable - FLYCwbY
Longitudinally water-blocked airfield lighting cable engineered for high-humidity areas, water-logged ducts, or direct soil burial where high groundwater exists. Incorporates a moisture barrier swelling tape beneath the screen to prevent water migration, coupled with a sturdy copper braided screen.
✈ Catalog Subtypes & Dimension Registry
Review the standard industrial sub-configurations and engineering designations of this cable series.
| CABLE VARIANT | VOLTAGE RATING | INDUSTRY STANDARD |
|---|---|---|
| FLYCwbY 1/2 kV (6/2.5 re) | 1/2 kV | DIN VDE 0265 |
| FLYCwbY 1/2 kV (6/2.5 rm) | 1/2 kV | DIN VDE 0265 |
| FLYCwbY 1.5/3 kV (6/2.5 re) | 1.5/3 kV | DIN VDE 0265 |
| FLYCwbY 1.5/3 kV (6/2.5 rm) | 1.5/3 kV | DIN VDE 0265 |
| FLYCwbY 2.5/5 kV (6/4 re) | 2.5/5 kV | DIN VDE 0265 |
| FLYCwbY 2.5/5 kV (6/4 rm) | 2.5/5 kV | DIN VDE 0265 |
| FLYCwbY 3.6/6 kV (6/4 re) | 3.6/6 kV | DIN VDE 0265 |
| FLYCwbY 3.6/6 kV (6/4 rm) | 3.6/6 kV | DIN VDE 0265 |
| FLYCwbY 3.6/6 kV (6/6 re) | 3.6/6 kV | DIN VDE 0265 |
| FLYCwbY 3.6/6 kV (6/6 rm) | 3.6/6 kV | DIN VDE 0265 |
Direct WhatsApp Specification Inquiry
Have custom design requests or need physical sample slices of FLYCwbY? Consult with our product engineering team instantly via WhatsApp.
Airport Lighting Cable - FL2XCY
Advanced airfield ground lighting cable insulated with Cross-linked Polyethylene (XLPE) for outstanding thermal and electrical properties. Handles high temperature loads up to 90°C and minimizes dielectric loss in medium voltage series runway circuits.
Catalog Subtypes & Dimension Registry
Review the standard industrial sub-configurations and engineering designations of this cable series.
| CABLE VARIANT | VOLTAGE RATING | INDUSTRY STANDARD |
|---|---|---|
| FL2XCY 3.6/6 kV (6/4 re) | 3.6/6 kV | IEC 60502-2 |
| FL2XCY 3.6/6 kV (6/4 rm) | 3.6/6 kV | IEC 60502-2 |
| FL2XCY 3.6/6 kV (6/6 re) | 3.6/6 kV | IEC 60502-2 |
| FL2XCY 3.6/6 kV (6/6 rm) | 3.6/6 kV | IEC 60502-2 |
| FL2XCY 6/10 kV (6/6 re) | 6/10 kV | IEC 60502-2 |
| FL2XCY 6/10 kV (6/6 rm) | 6/10 kV | IEC 60502-2 |
Direct WhatsApp Specification Inquiry
Have custom design requests or need physical sample slices of FL2XCY? Consult with our product engineering team instantly via WhatsApp.
Airport Lighting Cable - FLN2XCY
Premium chemical-resistant and anti-termite airfield ground lighting cable. Built with premium XLPE insulation, copper wire screen, and a hard-extruded Polyamide (Nylon) protective layer that acts as an impermeable barrier to aggressive tropical termites and chemical agents like kerosene, aviation fuel, and Skydrol oil.
✈ Catalog Subtypes & Dimension Registry
Review the standard industrial sub-configurations and engineering designations of this cable series.
| CABLE VARIANT | VOLTAGE RATING | INDUSTRY STANDARD |
|---|---|---|
| FLN2XCY 3.6/6 kV (6/4 re) | 3.6/6 kV | IEC 60502-2 |
| FLN2XCY 3.6/6 kV (6/4 rm) | 3.6/6 kV | IEC 60502-2 |
| FLN2XCY 3.6/6 kV (6/6 re) | 3.6/6 kV | IEC 60502-2 |
| FLN2XCY 3.6/6 kV (6/6 rm) | 3.6/6 kV | IEC 60502-2 |
| FLN2XCY 6/10 kV (6/6 re) | 6/10 kV | IEC 60502-2 |
| FLN2XCY 6/10 kV (6/6 rm) | 6/10 kV | IEC 60502-2 |
Direct WhatsApp Specification Inquiry
Have custom design requests or need physical sample slices of FLN2XCY? Consult with our product engineering team instantly via WhatsApp.
Performance Attributes
- High Dielectric Resistance: Premium grade PVC (FLYCY) or XLPE (FL2XCY) for stable voltage endurance in series loops.
- Fuel & Chemical Barrier: Polyamide (Nylon) protective layer on FLN2XCY prevents degradation from jet fuel, kerosene, and Skydrol.
- Water Propagation Stop: Water-swellable swelling tape on FLYCwbY blocks longitudinal water migration along the screen.
- Concentric Ground Screen: Helical concentric copper wires and binder tape act as low-impedance ground and rodent deterrent.
Target Project Application
- Primary airfield series circuits powered by Constant Current Regulators (CCR)
- Secondary airfield visual lighting connections (CCR isolating transformers to light fixtures)
- Runway edge, centerline, threshold, and touchdown zone light connections
- Approach visual lighting networks and PAPI (Precision Approach Path Indicators)
- Taxiway edge, centerline, and guidance signage circuit cabling
- Helipad and military airfield primary power loops
Initiate Dynamic Specification & Sample Request
Would you like to examine certified test reports (Partial Discharge charts, impulse load resistance grids) or secure actual physical cut-away sample slices of this cable series for your technical board analysis?